Hoge Intensiteit Obstakel
Verlichting
 |
-
Stand alone
design with integrated photocell, power supply, flasher and monitoring. Can also be used in a
system with multiple lights with a CIP100 or CIP200
controller.
- Optional external automatic flash synchronisation between
systems.
- Simple connection cables for easy
installation
- Complies with ICAO Annex 14 for type A and B obstruction
lights
- Complies with FAA AC150/5345-43F for type L-856 and
L857.
- Flashing 40/60 fp'; white (depending on model)
- Effective intensity ICAO type A: 200,000cd/20,000cd/2,000cd
nominal
- Effective intensity ICAO type B:
100,000cd/20,000cd/2,000cd nominal
- Effective intensity FAA L-856: 270,000cd/20,000cd/2,000cd
nominal
- Effective intensity FAA L-857: 140,000cd/20,000cd/2,000cd
nominal
- Horizontal beam coverage: 120º, vertical beam profile: 3º
minimum
- Operating voltage 110-245 Vac 50/60
Hz.
- Over voltage protection Class III
(IEC61643-1)
- Ingress Protection IP65. Operating temperature -55ºC to
+55ºC
- Stainless steel housing
- Dimensions (LXWXH) 570 X 460 X 255 and 35
kg.
|
|
brochure |
|